WE ARE Authorized Distributor for 2B Technologies'
Entire Range of analytical instruments for atmospheric and environmental measurements.
2B Technologies is based in Colorado, USA and specializes in miniaturized and portable instruments for measurements of ozone, NOx, black carbon and mercury. These lightweight, low-power instruments are suited to both ambient and industrial measurements and are highly precise and accurate. Therefore, they have been designated as a Federal Equivalent Method (FEM) by the US EPA. More than 1300 scientific papers, theses, presentations and posters have cited and made use of 2B Tech Ozone Monitors and Calibrators. Moreover, each instrument comes with NIST Traceable calibration. Gordon Solutions is equipped to provide fastest delivery, service and calibration support for the entire 2B Tech range in India.
Industrial Ozone Monitors Models 106-L, 106-M, 106-MH and 106-H
- For industrial ozone applications, 2B Tech offers the Model 106-L, 106-M, 106-MH and 106-H Ozone Monitors, where L, M, MH and H refer to Low (0-100 ppm), Medium (0-1,000 ppm), Medium-High (0-10,000 ppm) and High (0-20 wt%) ozone concentrations, respectively.
- Detects Ozone on the absolute measurement principle of UV Absorption at 254 nm with an accuracy of 1.5 ppb (for Model 106-L) or 2% of reading.
- All four models are available in either a standard enclosure or NEMA enclosure.
- Attractive features like Internal Data Logger, USB and RS-232 output, Two 2-level relays for control purposes, etc. Optional features like Bluetooth option for wireless data transmission, and Multi-channel air sampling configuration
Model UV-106-W
Download Brochure
Aqueous Ozone Monitor Model UV-106-W
- The Model UV-106-W Aqueous Ozone Monitor uses the patented MicroSparge™ technology to measure dissolved ozone in water with high precision and accuracy of 0.05 ppm or 1% of reading.
- Unlike most dissolved ozone sensors, the instrument does not make use of a membrane that will foul over time. Instead, dissolved ozone is measured by nearly complete sparging (bubbling) of ~2 mL of water with ozone-scrubbed ambient air.
- Because ozone is measured in the gas phase, provides interference-free measurement of dissolved ozone in ultrapure or "dirty" water. Interferences from suspended particles and dissolved inorganic and organic compounds are removed, making the instrument applicable to both ultrapure water and “dirty” water, such as drinking water.
- Salient features include NEMA water-proof housing, Internal Data Logger, both Serial and User-scalable Analog outputs, LED Alarms, etc.
Model 202 Ozone Monitor
- Designated Federal Equivalent Method (FEM), EQOA-0410-190.
- Accurate and precise measurements of ozone ranging from low ppb (precision of ~1.5 ppb) up to 250,000 ppb (0-250 ppm) based on the well-established technique of absorption of UV light at 254 nm.
- Lightweight and low power consumption, thus well suited for applications such as Vertical profiling, Long-term monitoring at remote locations, Long-term monitoring at remote locations, among others.
- Many attractive features including Internal Data Logger, 0-2.5 V Analog output, RS-232 output, Flash card memory and a quiet, long-life internal air pump. Optional features: External particle filter, Bluetooth, GPS, Rechargeable lithium-ion battery, High-altitude upgrade, Low-power option.
Model 205 Dual Beam Ozone Monitor
- The fastest UV-based ozone monitor in the market, hence especially desirable for aircraft and balloon measurements where high spatial resolution is needed.
- Designated Federal Equivalent Method (FEM), EQOA-0410-190.
- Use of two detection cells for improved precision, baseline stability, and response time. Accurate and precise measurements of ozone in Linear Dynamic Range of (0-250 ppm) with a resolution of 0.1 ppb based on the well-established technique of absorption of UV light at 254 nm.
- Many attractive features including Internal Data Logger, 0-2.5 V Analog output, RS-232 output, Flash card memory and a quiet, long-life internal air pump. Optional features: External particle filter, Bluetooth, GPS, Rechargeable lithium-ion battery, High-altitude upgrade, Low-power option.
Model 211 Scrubberless Ozone Monitor
- The World's Most Accurate Ozone Monitor having Linear Dynamic Range of 0 to 2 ppm with a resolution of 0.1 ppb.
- Designated Federal Equivalent Method (FEM), EQOA–0514–215.
- Proven Dual-beam ultraviolet (UV) absorption method in combination with patented (US Patent No. 8,395,776 B2) gas-phase scrubber technology to measure ozone virtually free of interferences. The instrument is ideally suited for measurements of ozone in heavily polluted air where interference is likely from particulates, mercury, or VOCs. based on the well-established technique of absorption of UV light at 254 nm.
- Many attractive features including Internal Data Logger, 0-2.5 V Analog output, RS-232 output, Flash card memory and a quiet, long-life internal air pump. Optional features: External particle filter, Bluetooth, GPS, Rechargeable lithium-ion battery, High-altitude upgrade, Low-power option.
Model 211-G Ozone Monitor
- Designated Federal Equivalent Method (FEM), EQOA–0514–215.
- Uses the proven ultraviolet (UV) absorption method in combination with patented heated graphite scrubber technology (U.S. Patent No. 10,295,517) to measure ozone virtually free of interferences. The instrument is ideally suited for measurements of ozone in heavily polluted air where interference is likely from particulates, mercury, or VOCs. based on the well-established technique of absorption of UV light at 254 nm.
- Many attractive features including Internal Data Logger, 0-2.5 V Analog output, RS-232 output, Flash card memory and a quiet, long-life internal air pump. Optional features: External particle filter, Bluetooth, GPS, Rechargeable lithium-ion battery, High-altitude upgrade, Low-power option.
Model POM
Download Brochure
Personal Ozone Monitor Model POM
- The World's Smallest Ozone Monitor - the next step in miniaturization of UV-based ozone monitors, which measures ambient ozone down to very low ppb levels.
- The basic POM unit has dimensions of 4 × 3 × 1.5 inches and weighs only 340 g / 450 g without / with battery. It has a built in GPS so that ozone measurements may be logged continuously along with geographic location.
- Detects Ozone on the direct measurement principle of UV Absorption at 254 nm with an accuracy of 1.5 ppb or 2% of reading.
- Applications include Personal exposure monitoring for studies of health effects of ozone, Health and safety monitoring at industrial sites that use ozone, Long-term monitoring at remote locations where power is highly limited, etc.
- Attractive features like Internal Data Logger, and USB/ Serial output.
All 2B Tech Ozone, NOx and Mercury Monitors come equipped with the revolutionary DewLine™ for Elimination of Water Vapor Interference.
For a comparison of all 2B Tech Ozone Monitors click here...